We design, install and maintain fire alarm systems, from single-zone conventional panels to fully addressable networks. Every system is commissioned, certified and added to a planned maintenance schedule.

What's included

  • System design and installation
  • Conventional and addressable systems
  • Commissioning and certification
  • Planned servicing and fault call-outs

You'll need this if

  • You are fitting out or extending a building and need a system designed and installed
  • Your existing alarm has not been serviced in the last six months
  • Your panel is showing faults or you are getting false alarms

What the rules say

BS 5839-1. The British Standard for fire alarms in non-domestic premises recommends a weekly test by the user and a service by a competent person at least every six months.

A summary, not legal advice. We will confirm what applies to your premises. See the full testing schedule.

How it works

  1. Tell us about your premises

    Call or send an enquiry with the size of the site, what is installed and what you need.

  2. We survey and quote

    We look at your premises and existing systems, then send a clear written quote.

  3. We do the work and keep the records

    Work is certified, your log book is updated and we remind you when the next visit is due.

Common questions

How often should a fire alarm be serviced?
BS 5839-1 recommends a service by a competent person at least every six months. We set up the schedule and remind you when visits are due.
Do you work on systems you did not install?
Yes. We can take over maintenance of existing systems. The first visit includes a full inspection so we know the system's condition.
Do you provide certificates?
Yes. Every installation, service and repair is recorded and certificates are issued on completion.
What is the difference between conventional and addressable systems?
A conventional panel shows which zone has triggered. An addressable panel identifies the exact device, which makes alarms and faults quicker to find in larger buildings.
What causes false alarms?
Common causes are dust, steam, cooking fumes, ageing detectors and detectors of the wrong type for the room. Regular servicing finds most of them before they become a problem.